In short
How can I test a sample of shisha briquettes the way the factory tests a batch?
Three of the factory's checks can be repeated on a sample: a burn test on an electric coil, a drop test and a caliper check. A batch fails on smell or smoke as the pieces warm up, high ash, cracked or broken pieces or pieces of uneven size or density, and the same signs can be looked for in a sample.
1. The factory's checks, in production order
Six checks run in the order of production, from the shell charcoal that arrives to the box that is closed. Three of them can be repeated on a sample.
-
Incoming shell charcoal
Each delivery is checked for moisture under 12%, at least 82% fixed carbon, at most 14% volatile matter, the ash content, the color of the ash.
-
Size
Four times a day, 20 pieces go under a digital caliper and each reading is logged.
-
Drying
48 hours or more per batch; moisture measured with a meter on every oven load; 2% at most.
-
Burn
Three pieces go on an electric coil; the time each takes to light and how long it burns are logged.
-
Drop
A lit piece is dropped on a hard tiled floor, from 30 cm for hexagonal, dome and finger shapes and from 100 cm for cube and flat shapes; it passes if it stays whole after three drops.
-
Packing
Each piece is inspected by hand as it is packed.
2. The burn test
Definition
burn test
A burn test lights a few pieces and records how long they take to light and how long they burn.
The factory's setting: three pieces go on an electric coil; the time each takes to light and how long it burns are logged. The same test needs only an electric coil and a timer.
-
Take three pieces
Take three pieces of one size and grade from the sample; test each size and grade the same way.
-
Light them on a coil
Place the three pieces on an electric coil and start a timer when the coil is switched on.
-
Record the time to light
Note when each piece is lit across its face.
-
Record the burn time
Note when each piece has burned down, and look at the ash it leaves.
Note
On the coil the factory has declared no target time. Its minutes come from timing a piece on a shisha bowl in use, until the smoking ends, and they are given for each size on the sizes compared. The time depends on the size of the piece, not its grade, so compare pieces of one size.
3. The drop test
Definition
drop test
A drop test lets lit pieces fall onto a hard floor from a set height and counts the drops each piece survives.
The factory's setting: a lit piece is dropped on a hard tiled floor, from 30 cm for hexagonal, dome and finger shapes and from 100 cm for cube and flat shapes; it passes if it stays whole after three drops. The height depends on the shape.
| Shape | Drop height |
|---|---|
| Cubes | 100 cm |
| Hexagonal, dome and finger shapes | 30 cm |
| Flat | 100 cm |
The longer hexagonal shisha briquette is dropped from the lower height. Use a hard tiled floor, and drop each lit piece three times.
4. The size check
The size is held to ±0.3 mm per side, the size tolerance of every standard size. The factory's check: four times a day, 20 pieces go under a digital caliper and each reading is logged.
Measure 20 pieces of the sample with a digital caliper and set each reading against the nominal size. Then weigh a kilogram and count the pieces: the declared pieces per kilogram of each size are on pieces per kg of each size.
5. What fails a batch
Four signs fail a batch at the factory, and each can be looked for in a sample.
- Smell or smoke as the pieces warm up
- High ash
- Cracked or broken pieces
- Pieces of uneven size or density
High ash is judged against the grade: the ash content of each grade is on ash by grade.
6. The retained sample
Definition
retained sample
A retained sample is a quantity kept back from a production batch, sealed and labeled, against which later questions about the batch are checked.
The factory keeps about 25 kg of every batch for 5 years, sealed in bags marked with the batch number and date.
A claim is made for quantity within one week and for quality within two weeks, counted from the day the container reaches the buyer's warehouse; the buyer's report is checked against the retained sample; a claim that holds is settled with a credit on the next order; the decision can go to a laboratory or a surveyor, and the cost is shared. How a claim runs is on claims and the retained sample.