Skip to the content
Menu

On file · Documents

Lab report: what it shows and how to read it

The lab report is one of the factory's papers for a container of shisha briquettes. This page explains how to read one for shisha charcoal; it shows no result, because no report is on file here.

Published by
PT Nargile Coconut Charcoal Indonesia
Published
Updated

In short

What does the lab report of an order show, and how do I read it?

One lab report is available for each order. It reports ash, which alone sets the grade, and moisture, volatile matter and fixed carbon. Read the ash against the grade's range, Platinum 1.6–1.9%, Super Premium above 1.9% and below 2.3%, Premium 2.3–2.5%, and check the basis each figure is on. The lab report does not decide how the cargo is carried; the UN N.4 self-heating test is a separate report.

1. One lab report per order

Definition

lab report

A lab report is a laboratory's statement of the values it measured on a sample, such as ash, moisture, volatile matter and fixed carbon.

A lab report is available, one per order. It gives the figures measured for that order.

Note

No result, laboratory, method or report number is shown on this site. A copy comes on request.

2. The four values on the report

The report gives four values. One of them sets the grade; the other three are reported beside it.

The four values of the lab report and the role each plays at this factory.
ValueWhat it isRole
Ash What is left once the charcoal has burnedSets the grade
Moisture The water in the piecesReported
Volatile matter What leaves the charcoal as gas when it is heated without airReported
Fixed carbon The solid carbon that remainsReported

Definition

fixed carbon

Fixed carbon is the part of a charcoal that remains as solid carbon once its moisture, volatile matter and ash are accounted for.

Definition

volatile matter

Volatile matter is the part of a charcoal that leaves it as gas when it is heated without air, given as a percentage of its weight.

Ash content alone decides the grade; the lab report also gives the moisture, the volatile matter and the fixed carbon. The ash content is the one figure to read first.

3. Reading the report

Read the ash against the range of the grade you ordered.

The ash range of each grade, as declared by the factory.
GradeAsh
Platinum 1.6–1.9%
Super Premium above 1.9% and below 2.3%
Premium 2.3–2.5%

Then check the basis. A figure given as received includes the moisture content of the sample; a figure on a dry basis leaves it out, so the two differ. Compare figures on the same basis, and note that fixed carbon is often given as the remainder of the other values rather than measured on its own.

The grade ranges are on a dry basis, so an ash figure is set against them on that basis.

Every limit the factory declares, from the shell charcoal to the dried pieces, is on the declared limits, and the grades on ash sets the grade.

4. What a lab report is not

A lab report describes quality. It does not decide how the cargo is carried: that is set by the self-heating test, a separate report, under the rules for UN 1361.

The IMDG Code classes a substance as self-heating by the UN N.4 test of the UN Manual of Tests and Criteria, which exposes cube samples of 25 mm and 100 mm at 140 °C and, in some cases, a 100 mm cube at 120 °C or 100 °C.

Source: Resolution MSC.556(108): Amendments to the International Maritime Dangerous Goods (IMDG) Code, Amendment 42-24 (opens in a new tab), International Maritime Organization, opened

Under special provision 978, the result of a UN N.4 self-heating test cannot be used to take UN 1361 out of the provisions of the IMDG Code.

Source: Resolution MSC.556(108): Amendments to the International Maritime Dangerous Goods (IMDG) Code, Amendment 42-24 (opens in a new tab), International Maritime Organization, opened

How the self-heating test works, and why it cannot exempt the cargo under special provision 978, is on the self-heating test.

5. Getting a copy

Ask for a copy of the lab report with the quote or with the order.

The checks that come before the report, in the factory, are on the checks before the report, and a lab report's place in a claim on a lab report in a claim.

Questions buyers ask

Does the lab report show that the cargo is safe to ship?
No. Under special provision 978, the result of a UN N.4 self-heating test cannot be used to take UN 1361 out of the provisions of the IMDG Code.
On which basis are the figures of a lab report given?
A lab report gives its figures either as received or on a dry basis, and the two differ by the moisture; compare figures on the same basis. The grade ranges are on a dry basis.
Can I see the lab report before I order?
The factory's lab report is available; one per order. Ask for a copy with your quote.

Sources

  1. Resolution MSC.556(108): Amendments to the International Maritime Dangerous Goods (IMDG) Code, Amendment 42-24 (opens in a new tab), International Maritime Organization — opened

Test a sample the same way

The sample form asks for the sizes and grades you want to compare and the address to send them to.

Request a sample